Magnum 6K32 & 6K32T Managed Switch Installation and User Guide (12/05)
40
www GarrettCom com
..
negotiation ports typically will not work properly. The 6K32T Switch’s RJ-45 ports
handle this situation by configuring the ports as per desire through MNS software port
settings and can check the port status of each port after the change.
When Magnum 6K32T RJ-45 copper ports are set for auto-negotiation and are
connected to another auto-negotiating device, there are 4 different speed and F/H modes
possible depending on what the other device supports. These are: (1) 100Mb full-duplex,
(2) 100Mb half-duplex, (3) 10 Mb full-duplex and (4) 10 Mb half-duplex.
General information -
Auto-negotiation per-port for 802.3u-compliant switches occurs when:
-- the devices at both ends of the cable are capable of operation at either 10
Mb or 100Mb speed and/or in full- or half-duplex mode, and can
send/receive auto-negotiation pulses, and . . .
-- the second of the two connected devices is powered up*, i.e., when
LINK is established for a port, or
-- the LINK is re-established on a port after being lost temporarily.
NOTE – Some NIC cards only auto-negotiate when the computer system
that they are in is powered up. These are exceptions to the “negotiate at
LINK – enabled” rule above, but may be occasionally encountered.
The auto-negotiation logic will attempt to operate in descending order and will normally
arrive at the highest order mode that both devices can support at that time. (Since auto-
negotiation is potentially an externally controlled process, the original “highest order
mode” result can change at any time depending on network changes that may occur). If
the device at the other end is not an auto-negotiating device, the 6K32T’s RJ-45 ports
will try to detect its idle signal to determine 10 or 100 speed, and will default to half-
duplex at that speed per the IEEE standard.
When operating in 100Mb half-duplex mode, cable distances and hop-counts
may be limited within that collision domain. The Path Delay Value (PDV) bit-times must
account for all devices and cable lengths within that domain. For Magnum 6K32T Fast
Ethernet switched ports operating at 100Mb half-duplex, the bit time delay is 50BT.