F125: DVCF Record <x>, invalid Number of Type-Point
Cause:
The Number of Data record defined for this Device/Configuration (DVCF) record <x> is not
within a valid range of records in the A164DTBL configuration table.
Remedy:
Review the section on configuring the A164DVCF table (Chapter 6:, Chapter 7:, and
Chapter 8:), and verify that the Number of Data is configured within a valid range of records
in the A164DTBL table.
F200: Error <x> on win open
Cause:
The BECO2200 DCA failed in its attempt to open a channel to WIN. The error code returned
was <x>.
Remedy:
Call the Customer Service department and report this error.
F201: Error <x> signaling A164-D-00 process
Cause:
The BECO2200 DCA was unable to signal one of its critical processes. The error code
returned was <x>.
Remedy:
Call the Customer Service department and report this error.
F202: No communication ports have been started
Cause:
No communication processes have been properly initialized. This is either due to the
configuration of the BECO2200 DCA or due to the process initialization itself.
Remedy:
Address all fatal and non-fatal error messages preceding this message.
F203: Error <x> creating A164-<y>-<z> exchange
Cause:
The BECO2200 DCA failed in its attempt to create the A164-<y>-<z> exchange. The error
code returned was <x>.
Remedy:
Call the Customer Service department and report this error.