CHAPTER 1: INTRODUCTION ML1600 SOFTWARE UPDATES
MULTILINK ML1600 ETHERNET COMMUNICATIONS SWITCH – INSTRUCTION MANUAL 1–23
Once the upgrade is started, the terminal emulation software will ask for the
installation file location.
Z Indicate the file location to begin the file transfer.
Make sure the Xmodem protocol is also selected in this file location
dialog window.
In some operating systems it maybe necessary to select the transfer option.
Z In this case, return to the HyperTerminal window used in step 5.
Z Select the Transfer > Send File menu item.
Z As shown below, enter the location of the new software file.
Z Select the Xmodem protocol.
Z Select the Send button and to begin the file transfer.
Z Once the file transfer is completed reboot the switch with the
reboot command or by cycling power.
Z Login to the switch and use the
show version command to verify
and upload the configuration file (if necessary).
1.7.4 Updating through the EnerVista Software
Use the following procedure to install the EnerVista Secure Web Management software.
Z Download the latest MultiLink firmware from the GE Multilin web
site.
Z Save this file on FTP or TFTP.
Ensure the FTP or TFTP path is configured. If using FTP, record the
FTP login name and password.