GENICOM Intelliprint cL160 User Guide 1-3
Positioning the Printer
When using an ultrasonic water vaporizer
Using tap or well water with ultrasonic water vaporizers disperses impurities into the air. These
impurities can accumulate inside the printer and cause print quality to deteriorate. If you install the
printer in the same room as an ultrasonic water vaporizer, use only filtered water in the water vapor-
izer.
Minimum Installation Clearances
Be sure to install the printer in a location that respects the minimum clearances indicated in the
illustrations below.
Top View
Front View
CAUTION: To avoid obstruction of the ventilation grills on the back and the side of the
printer, position the printer no less than 150 mm from the wall on the right side, 100 mm
from the wall on the left side, and 200mm from the wall at the back. Obstructing the venti-
lation grills can cause the printer to overheat and become a fire hazard. To allow easy rou-
tine maintenance, replacement of consumables, proper operation and ensure satisfactory
performance, confirm that the printer’s position is as illustrated below.
100mm
200mm
150mm
600mm
100mm
150mm