IMAGETEAM™ 2020/4620 System Manual 3 - 7
Imager Name
You are able to assign a name to each imager you are using. It will be helpful to
name the imagers if you have multiple imagers linked to one base so that you will
be able to control the imager receiving imaging commands sent from the base.
The default name for an IT4620 is “IT4620”. If you have more than one IT4620
linked to a base, the first imager that is linked to the base receives commands
addressed using this name. If you wish to change the name, you may change it
via a serial command (refer to "Menu Command Syntax" on page 12-1) or via a
bar code command. To change the name serially, unlink all except one of the
IT4620s from the base. Send “:IT4620:BT_NAM
name
.”, where
name
is the new
imager name. If you wish to change the name of additional IT4620s, re-link them
one at a time and repeat the “:IT4620:BT_NAM
name
.”
command for each
imager.
If you wanted set up your imagers with names 0001-0007, you may scan the bar
codes below.
Scan the Reset bar code after each name change and wait for the
scanner to re-link to the base before scanning the next bar code to name the next
imager.
0001
0002
0003
0005
0007
0004
0006
Reset