HP (Hewlett-Packard) 2040D Network Router User Manual


 
Series 2040 Test System
Series 2040 Maintenance Manual V2.00Selftest & Calibration
12
: (Colon) signifies that the following number indicates the amount
of iterations to perform of the previous sequence.
, (Comma) shares the definition of ‘E’ as a separator between
sequences.
- (Dash) signifies inclusive or ‘through’.
EXAMPLE: E1-3:5,6-100:2,1-5
This sequence executes tests 1 through 3 five times, tests 6 through
100 two times, and tests 1 through 5 once.
If a single test or a group of selected tests is to be run once, 10
times, or 100 times, use the mouse to select the appropriate button
on the upper left. If the test or group is to be run at some other
number, place the mouse pointer in the box to the direct left of the
stop button, and the Windows text tool will appear in place of the
mouse pointer. Click the left mouse button while texttool is
displayed in the box, and a blinking cursor appears in the box. The
user can now enter any number from 1 to 999 for the number of
times a test should run.
For diagnostic purposes, click
the mouse button on the small
box in the upper left corner of
the menu next to “All Tests”.
Select the “1" button, and the
program will run all of the
functional tests once, while reporting the data to wherever it was
directed from the ”Report Utilities" box. For diagnostics this path
should include the “File” and “Printer” categories, and the “Fail
Data” and “Diagnostic File” options.
5) If any of the Functional programs fail, check these common
problems:
SELFTEST ASSEMBLY IMPROPERLY INSTALLED - Check to make
sure the assembly is properly installed on the Patchboard. Also,