HP (Hewlett-Packard) 6205B Power Supply User Manual


 
TM 11-6625-2965-14&P
SECTION VI
REPLACEABLE PARTS
6-1 INTRODUCTION
6-2 This section contains information for ordering
replacement parts. Table 6-4 lists parts in alpha-
numeric order by reference designators and provides
the following information:
a.
Reference Designators. Refer to Table 6-1.
b.
Description. Refer to Table 6-2 for ab-
breviations.
c. Total Quantity (TQ). Given only the first
time the part number is listed except in instruments
containing many sub-modular assemblies, in which
case the TQ appears the first time the part number
is listed in each assembly.
d.
Manufacturer’s Part Number or Type.
e. Manufacturer’s Federal Supply Code Num-
be r.
Refer to Table 6-3 for manufacturer’s name and
address.
f. Hewlett-Packard Part Number.
9.
Recommended Spare Parts Quantity (RS)
for complete maintenance of one instrument during
one year of isolated service.
h.
Parts not identified by a reference desig-
nator are listed at the end of Table 6-4 under Me-
chanical and/or Miscellaneous. The former consists
of parts belonging to and grouped by individual as-
semblies; the latter consists of all parts not im-
mediately associated with an assembly.
6-3 ORDERING INFORMATION
6-4 To order a replacement part, address order or
inquiry to your local Hewlett-Packard sales office
(see lists at rear of this manual for addresses).
Specify the following information for each part:
Model, complete serial number, and any Option or
special modification (J) numbers of the instrument;
Hewlett-Packard part number; circuit reference des-
ignator; and description. To order a part not listed
in Table 6-4, give a complete description of the
part, its function, and its location.
Table 6-1.
Reference Designators
A
= assembly
B
= blower (fan)
C
= capacitor
CB
= circuit breaker
CR
= diode
DS
= device, signal-
ing (lamp)
E
= miscellaneous
electronic part
F = fuse
J
= jack, jumper
K
= relay
L = inductor
M = meter
Table 6-1.
Reference Designators (Continued)
P
= plug
v
= vacuum tube,
Q
= transistor
neon bulb,
R= resistor
photocell, etc.
s = switch
VR
= zener diode
T
= transformer
x
= socket
TB = terminal block
z
= integrated cir-
TS
= thermal switch
cuit or network
Table 6-2. Description Abbreviations
A=
ac =
assy. =
bd =
bkt =
O
C .
cd =
coef =
comp .
CRT =
CT =
dc =
DPDT =
DPST =
elect =
encap=
F=
o
F .
fxd =
Ge =
H=
Hz =
IC =
ID =
incnd .
k=
m=
M=
P=
met. =
ampere
alternating
current
assembly
board
bracket
degree
Centigrade
card
coefficient
composition
cathode-ray
tube
center-tapped
direct current
double pole,
double throw
double pole,
single throw
electrolytic
encapsulated
farad
degree
Farenheit
fixed
germanium
Henry
Hertz
integrated
circuit
inside diameter
incandescent
kilo = 10
3
mini = 10-3
mega . 10
6
micro = 10
-6
metal
mfr .
mod. =
mtg =
n.
NC =
NO =
NP =
obd =
OD =
P=
P.C. =
pot. =
p-p .
ppm =
pvr =
rect =
rms =
Si
SPDT =
SPST =
SS =
T=
tan. =
Ti =
v=
var =
WW =
w=
manufacturer
modular or
modified
mounting
nano . 10
-9
normally closed
normally open
nickel-plated
ohm
order by
description
outside
diameter
pico =
10-
12
printed circuit
potentiometer
peak-to-peak
parts per
million
peak reverse
voltage
rectifier
root mean
square
silicon
single pole,
double throw
single pole,
single throw
small signal
slow-blow
tantulum
titanium
volt
variable
wirewound
Watt
6-1