HP (Hewlett-Packard) 686784-001 Server User Manual


 
16 HP ProLiant DL560 Server Maintenance and Service Guide
Power down the server ("Powering Down the Server" on page 16).
If you must remove a server from a rack or a non-hot-plug component from a
server, power down the server.
Remove the server from the rack ("Removing the Server from the Rack" on
page 18
).
If the rack environment, cabling configuration, or the server location in the
rack creates awkward conditions, remove the server from the rack.
Powering Down the Server
WARNING: To reduce the risk of personal injury, electric
shock, or damage to the equipment, remove the power cord to
remove power from the server. The front panel Power On/Standby
button does not completely shut off system power. Portions of the
power supply and some internal circuitry remain active until AC
power is removed.
IMPORTANT: If installing a hot-plug device, it is not necessary to
power down the server.
1. Back up the server data.
2. Shut down the operating system as directed by the operating system
documentation.
3. If the server is installed in a rack, press the UID LED/button on the front
panel (1). Blue LEDs illuminate on the front and rear panels of the server.
4. Press the Power On/Standby button to place the server in standby mode (2).
When the server activates standby power mode, the system power LED
changes to amber.