HP (Hewlett-Packard) 686784-001 Server User Manual


 
Server Component Identification 93
Item Description Fan Zone
5 Fan 5 Processor
6 Fan 6 Processor
7 Fan 7 Processor
8 Fan 8 Processor
9 Fan 9 Power supply
10 Fan 10 Power supply
NOTE: For information on fan redundancy, refer to "Redundant
Hot-Plug Fan Option (on page 93
)."
Redundant Hot-Plug Fan Option
The server supports redundant hot-plug fans to provide proper airflow to the
system if a primary fan fails. The server airflow is divided into two fan zones:
processor and power supply.
In the standard configuration, five fans cool the server: fans 1, 3, 5, and 7 in the
processor zone, and fan 9 in the power supply zone.
For the redundant configuration, fans 2, 4, 6, 8, and 10 are added to back up the
primary fans. This allows the server to continue operation in non-redundant
mode with one fan failure in either zone.
The server shuts down in the following scenarios:
At POST:
The BIOS suspends the server for 5 minutes if a cautionary temperature
level is detected. If the cautionary temperature level is still detected after
5 minutes, the BIOS performs an orderly shutdown and then restarts.
This process repeats until the cautionary temperature level is no longer
detected.