HP (Hewlett-Packard) 8080 ELITE BUSINESS Personal Computer User Manual


 
Heat Dissipation
Max STD PS
Typical STD PS idle
Max EPA 87/89/85% @ 20/50/100% load PS
Typical EPA 87/89/85% @ 20/50/100% load PS idle
1410 BTU/hr
222 BTU/hr
1255 BTU/hr
171 BTU/hr
356 kg-cal/hr
56 kg-cal/hr
316 kg-cal/hr
43 kg-cal/hr
Power Supply
Operating Voltage Range (STD PS)
Operating Voltage Range (EPA 87/89/85% @ 20/50/100%
load PS)
Rated Voltage Range (STD PS)
Rated Voltage Range (EPA 87/89/85% @ 20/50/100% load
PS)
Rated Line Frequency
115V
90-264 VAC
90-264 VAC
100-240 VAC
100-240 VAC
50-60 Hz
230V
90-264 VAC
90-264 VAC
100-240 VAC
100-240 VAC
50-60 Hz
Power Output 320W 320W
Rated Input Current (maximum)
1
STD PS
EPA 87/89/85% @ 20/50/100% load PS
5.5A @ 115 VAC
5.5A @ 115 VAC
2.75A @ 230 VAC
2.75A @ 230 VAC
1
This system utilizes an active power factor corrected power supply. This allows the system to pass the CE mark
requirements for use in the countries of the European Union. The active power factor corrected power supply also has the
added benefit of not requiring an input voltage range select switch.
Table I-1 Specifications (continued)
264 Appendix I Specifications