Release Notes for 07.8.04 Software Fixes
34609 A 10 Gigabit Ethernet link stays up when the egress
side of the link is disabled. No link-fault signal (LFS)
is configured.
10GE link 07.6.06 07.8.01b
35199 When forwarding sFlow packets, the routing switch
crashes with a data access exception in the
“sw_12_get_outgoing_port_by_da_match” routine
due to an invalid port number.
sFlow 07.6.06 07.8.01b
36363 After you add a VLAN group with a large number of
configured VLANs or after a system reload, the
following error message is displayed repeatedly:
WARN: Out of timer entry
VLAN 07.8.01 07.8.01b
41689 The show pid value displayed in show tech
command output causes a brief CPU utilization
spike.
CPU 07.6.06 07.8.01b
43660 If you generate an SSH key by entering the crypto
key generate rsa command, the routing switch
crashes with a Data Access Exception in the “ssh-
vsnprintf_internal” routine.
SSHv2 07.8.01 07.8.01b
43861 When you enable SSH, a routing switch may reload
with a Program Exception in the
“ssh_private_key_derive_public_key” routine.
SSH 07.8.00 07.8.01b
44042 A system reload may occur when you start an SSH
session on a routing switch with a crash dump that
includes “ssh_server_destroy”.
SSH 07.8.00 07.8.01b
44364 The OSPF neighbor fails to come up because of an
authentication key failure.
OSPF 07.6.06 07.8.01b
45071 After you delete the ACL statement, access-list
100 deny ip 0.0.0.0 0.255.255.255 any, error
messages and locked CAM entries are displayed.
ACL, CAM 07.6.06 07.8.01b
45198 Port 280 stays open if you enter the following
commands:
no web-management http
no web-management hp-top-tools
Web
Management
07.8.01 07.8.01b
45319 When you enter the ip rebinding acl all command,
the following error message is displayed in the log:
Exceed max DMA 9 L4 cam resource,
using flow-based ACL instead.
ACL 07.8.00 07.8.01b
46742 An ACL on a Web access-group router does not
send a reset (RST) bit until after the TCP 3-way
handshake completes.
ACL 07.8.01 07.8.01b
46777 When the config-trunk-ind value is configured, the
global configuration of the sFlow sampling rate is
not applied to secondary trunk links on system
startup.
sFlow 07.6.06 07.8.01b
Bug ID Bug Description Protocol/
Feature
Version
Found
Version
Fixed