Hitachi CP-X3021WN Projector User Manual


 
9
RS-232C Communication (continued)
Communication settings
1. Protocol
19200bps,8N1
2. Command format
("h" shows hexadecimal)
Byte Number
01 2 3456
789101112
Command
Action
Header Data
Header
code
Packet
Data
size
CRC
ag
Action Type
Setting
code
L H L H L H L H L H L H
<SET>
Change setting to
desired value [(cL)(cH)]
by [(eL)(eH)].
BEh EFh 03h 06h 00h
(aL) (aH) 01h 00h (bL) (bH) (cL) (cH)
<GET>
Read projector
internal setup value [(bL)
(bH)] .
(aL) (aH) 02h 00h (bL) (bH) 00h 00h
<INCREMENT>
Increment setup value
[(bL)(bH)] by 1.
(aL) (aH) 04h 00h (bL) (bH) 00h 00h
<DECREMENT>
Decrement setup value
[(bL)(bH)] by 1.
(aL) (aH) 05h 00h (bL) (bH) 00h 00h
<EXECUTE> Run a
command [(bL)(bH)].
(aL) (aH) 06h 00h (bL) (bH) 00h 00h
[Header code], [Packet], [Data size]
Set [BEh, EFh, 03h, 06h, 00h] to byte number 0
~
4.
>&5&ÀDJ@
For byte number
5, 6,
refer to
RS-232C Communication / Network command
table
(
17
)
.
[Action]
Set functional code to byte number 7, 8.
<
SET
> = [01h, 00h], <
GET
> = [02h, 00h], <
INCREMENT
> = [04h, 00h]
<DECREMENT> = [05h, 00h], <EXECUTE> = [06h, 00h]
Refer
to
the
command table above.
[Type], [Setting code]
For byte number
9 12
, refer to
RS-232C Communication / Network command
table
(
17
)
.