31
PJLink command (continued)
Commands Control Description Parameter or Response
ERST ? Error Status inquiry
1st byte: Refers to Fan error; one of 0 to 2
2nd byte
: Refers to Lamp error; one of 0 to 2
3rd byte: Refers to Temptrature error; one of 0 to
2
4th byte: Refers to Cover error; one of 0 to 2
5th byte: Refers to Filter error; one of 0 to 2
6th byte: Refers to Other error; one of 0 to 2
The mearning of 0 to 2 is as given below
0 = Error is not detected; 1 = Warning; 2 =
Error
LAMP ? Lamp Status inquiry
1st number (digits 1 to 5): Lamp Time
2nd number : 0 = Lamp off, 1 = Lamp on
INST ? Input Source List inquiry 11 12 22 23 31 41 51 52
NAME ? Projector Name inquiry
Responds with the name set in "PROJECTOR
NAME" of "NETWORK"
INF1 ?
Manufucturer's Name
inquiry
HITACHI
INF2 ? Model Name inquiry
Your model name,
"CP-X2021WN",
"CP-X2521WN" or "CP-X3021WN".
INFO ? Other Information inquiry
Responds with the factory information and so
on
CLSS ? Class Information inquiry 1
NOTE
• The password used in PJLink
TM
is the same as the password set in
the Web Brouwser Comtrol. To use PJLink
TM
without authentication, do not set
any password in Web Browser Control.
• For specications of PJLink
TM
, see the web site of the Japan Business
Machine and Information System Industries Association.
URL: http://pjlink.jbmia.or.jp/