62
POWER
indicator
LAMP
indicator
TEMP
indicator
Description
Lit In
Orange
Turned
off
Turned
off
The projector is in a standby state.
Please refer to the “Turning the power on” (
20) and
“Turning the power off” (
23).
Blinking
Green
Turned
off
Turned
off
The projector is warming up.
Please wait.
Lit In
Green
Turned
off
Turned
off
The projector is on and ready.
Ordinary operations may be performed.
Blinking
Orange
Turned
off
Turned
off
The projector is cooling down.
Please wait.
Blinking
Red
(varies) (varies)
The projector is cooling down. An error has been
detected.
Please wait until the POWER indicator finishes blinking,
and then try the suggested solution, referring to the
following error descriptions.
Blinking
Red
or
Lit In
Green
Lit In Red
Turned
off
The lamp will not light, and there is a possibility that
interior of the projector has overheated.
Please turn the power off, and allow the projector to cool
down for at least 20 minutes. After the projector has
cooled down sufficiently, please confirm the following
items, and then turn the power on again.
• Is there blockage of the air passage aperture?
• Is the air filter dirty?
• Does the peripheral temperature exceed 35°C?
If the same indication is displayed after trying the
solutions above, please change the lamp according to the
directions in “Lamp” (56, 57).
Troubleshooting
Regarding the indicator lamps
The meanings of the lighting patterns of the POWER indicator, the LAMP
indicator, and the TEMP indicator are described in the table below. Please follow
the instructions within the table. If the same indication is displayed after trying
the solutions below, or if an indication other than the following appears, please
contact your dealer or service company.
(Continued on next page)