Honeywell MS2430 Barcode Reader User Manual


 
27
Cable Installation (Interface Specific)
RS485
The following steps describe how to properly install the cables for a RS485 application. The scanner/Diva
scale must then be configured to match the host’s RS485 parameters. Cable installation alone does not
guarantee that the scanner will communicate properly with the host system.
Note: Configuration bar codes are located in the MetroSelect Configuration Guide (PN 00-02407x) and the
MS2x20 Stratos Series Scanner/Diva Scale Configuration Addendum (PN 00-02272x).
1. Turn off the host system.
2. Plug the 10-pin RJ45 end of the RS485 interface cable (PN 57-57212x-N-3) into the 10-pin socket labeled
Scanner Host 46xxon the bottom of the scanner. Refer to the figure on page 28.
3. Connect the other end of the RS485 cable to communication port 9 on the host device.
Stop: Before continuing, verify that the RS485 cable is connected to the appropriate interface socket on
the scanner. An incorrect cable connection can cause communication problems or potential
damage to the scanner and/or terminal.
Note: Plugging the scanner into the serial port of the host device does not guarantee that scanned
information will appear at the host device. A software driver and correct configuration settings are
also required for proper communication to occur.
Steps 4 and 5 are for dual cable interfaces where the scale and the scanner connect to the host with their own
separate communication cables. Skip to step 6 for a single cable interface where the scale and scanner
connect to the host with a single cable.
4. Plug the 10-pin RJ45 end of the dual interface cable (PN 57-57000x-N-3) into the 10-pin socket labeled
Scale RS232 to Hoston the bottom of the bottom of the scanner.
5. Connect the other end of the dual interface cable (PN 57-57000x-N-3) into the appropriate communication
port on the host’s scale.
6. Plug the optional remote scale display cable (PN 46-00375, 46-00376, or 46-00377) into the 10-pin socket
labeledScale to Display’ on the bottom of the scanner.
7. Plug the external power supply (46-002xx) into the 3-pin Molex socket labeledDC Power Inon the bottom
of the scanner.
Note: Check the AC input requirements of the power supply to make sure the voltage matches the AC
outlet. The outlet should be located near the equipment and be easily accessible.
Using a switched AC outlet is recommended. The switch should be located on the operator’s side
of the checkout counter in close proximity to the scanner to facilitate calibration and service of the
unit.
8. Connect AC power to the transformer. If the AC outlet is equipped with an on/off switch, turn the power on.