Honeywell MS2430 Barcode Reader User Manual


 
29
Cable Installation (Secondary Honeywell Scanner)
The following steps describe how to properly install the cables between a secondary Honeywell scanner and
the MS2420/MS2430. The MS2420/MS2430 and the secondary scanner must then be configured to
communicate properly. Cable installation alone does not guarantee that the MS2420/MS2430 will
communicate properly with the host system and secondary scanner.
Note: Contact a customer service representative before connecting another manufacturer’s scanner to the
MS2420/MS2430 as a secondary scanner.
Configuration bar codes are located in the MS2x20 Stratos Series Scanner/Diva Scale Configuration
Addendum (PN 00-02272x) under Scanner Configuration Bar Codes: Auxiliary Port, Quick Start for a
Secondary Honeywell Scanner.
1. Refer to pages 22 - 27 for the type of interface (RS232, RS485, etc.) required for your application. Follow
the cable installation steps under the appropriate interface before continuing. Once the communication
and power cables have been installed follow step 2 below for the secondary scanner installation.
2. Connect the straight end of the RS232 PowerLink AUX cable (PN 57-57099x-3 or PN 57-57099x-3-12) into
the RS232 socket of the secondary scanner (see figure on page 30).
3. Connect the angled end of the RS232 AUX cable (PN 57-57099x-3 or PN 57-57099x-3-12) into the 10-pin
socket labeled Aux RS232 Inon the bottom of the MS2420/MS2430.
Important: The MS2420/MS2430 series’ aux port requires the signals; transmit, receive, RTS & CTS
from the secondary scanner.
For Rev G Units or later: The MS2420/MS2430’s auxiliary port will support 5VDC devices with a
700mA maximum current.
For Rev F units or earlier: The MS2420/MS2430’s auxiliary port will support 5VDC devices with a
150mA maximum current. If the auxiliary device exceeds this specification,
an external power supply will be required to power the auxiliary device. The
following Honeywell scanners can receive power from MS2420/MS2430: the
MS9520, MS9540, and the MS5145.
4. This step is required for secondary devices that require >5VDC and/or 700mA current to operate. Skip to
step 5 if the secondary device requires ≤ 5VDC. Plug the power supply into the secondary scanner’s
PowerLink cable (PN 57-57099x-3 or PN 57-57099x-3-12) and connect AC power to the secondary
scanner.
Note: Check the AC input requirements of the power supply to make sure the voltage matches the
AC outlet. The outlet should be located near the equipment and be easily accessible.
5. Configure the MS2420/MS2430 and the secondary scanner. The auxiliary input port’s data format must
match the main output format of the secondary scanner.
Note: Refer to the MS2x20 Stratos Series Scanner/Diva Scale Configuration Addendum
(PN 00-02272x) under Scanner Configuration Bar Codes: Auxiliary Port, Quick Start for a
Secondary Honeywell Scanner.