Honeywell MS2430 Barcode Reader User Manual


 
42
Diagnostic Indicator Display
Error
Code
Description
26
LASER #3 (LEFT HORIZONTAL) HIGH CURRENT WARNING The laser in the vertical scanning
subsystem is drawing excessive current. This could be a warning for a future total failure. Have
the unit checked at an authorized service center when convenient.
27
LASER #1 (VERTICAL) UNDERCURRENT WARNING – The laser in the vertical scanning
subsystem is drawing too little current. The laser is probably not on. This could be the result of a
loss of the required set point in memory. Have the unit checked at an authorized service center.
28
LASER #2 (RIGHT HORIZONTAL) UNDERCURRENT WARNING – The laser in the right
horizontal scanning subsystem is drawing too little current. The laser is probably not on. This
could be the result of a loss of the required set point in memory. Have the unit checked at an
authorized service center.
29
LASER #3 (LEFT HORIZONTAL) UNDERCURRENT WARNINGThe laser in the left vertical
scanning subsystem is drawing too little current. The laser is probably not on. This could be the
result of a loss of the required set point in memory. Have the unit checked at an authorized
service center.
31
MOTOR #1 (VERTICAL) ERROR The motor in the vertical scanning subsystem denotes a
failure. The scanner will try three times to correct the motor operation. If the motor error persists,
the vertical scanning subsystem will be shut down and this error code will remain on the
Diagnostic Indicators.
32
MOTOR #2 (HORIZONTAL) ERROR The motor in the horizontal scanning subsystem denotes a
failure. The scanner will try three times to correct the motor operation. If the motor error persists,
the horizontal scanning subsystem will be shut down and this error code will remain on the
Diagnostic Indicators.
34
Motor #1 (VERTICAL) SPEED ERRORThe motor in the vertical section cannot be speed
controlled as desired. Have the unit checked at an authorized service center.
35
Motor #2 (HORIZONTAL) SPEED ERRORThe motor in the horizontal section cannot be speed
controlled as desired. Have the unit checked at an authorized service center.