Honeywell MS2430 Barcode Reader User Manual


 
31
EAS Deactivation
SW1 and SW2 are the switch banks inside the Checkpoint Device that set the deactivation range. The
following is a list of Checkpoint recommended switch bank settings.
Base Model Checkpoint Recommended Switch Bank Settings
MS2420 SW1 & SW2 switches 1 and 6 set to ON
MS2430 SW1 & SW2 switches 1 and 6 set to ON
All MS2420/MS2430 models have a connector labeled EAS In on the bottom of the unit. An optional EAS
cable (PN 52-52511 or 52-52556) is available for purchase for connection between the Checkpoint Device and
the MS2420/MS2430.
Figure 23. EAS Cable Connection (Bottom of MS2420/MS2430)
The following figure shows the location of the EAS deactivation area for the MS2420/MS2430. It is important
to pass the entire tag through this area to deactivate the security tag.
Figure 24. EAS Deactivation Area