Honeywell MS9520 Scanner User Manual


 
22–2
Activation Mode Features
³ 9 1 9 6 0 0
~ Variable Laser-On Time Out – Scan this bar
code with a code byte sequence (on page 16–1)
that represents the desired time out increment.
The configurable time increment (1-second
increments) selected is the scanning laser-on
time.
³ 1 2 0 3 1 4
Allow Full Laser-On CycleThe laser stays on
for a full cycle even when a bar code is scanned
and transmitted.
³ 4 1 8 3 2 4
Blinky ModeThe laser turns on after the
selected activation trigger is detected. The laser
will blink on/off for approximately 30 seconds.
³ 1 1 8 1 1 1
Transmit a NO READ Message on Laser Time
OutIf the scanning cycle terminates without
scanning a bar code during the cycle, a NO READ
message is transmitted with the termination of the
scanning cycle.
³ 1 1 8 1 0 1
Do Not Transmit a NO READ Message on Laser
Time Out
³ 1 1 8 3 1 1
Activate the LED during the NO READ
TransmissionThe LED is output with the NO
READ message.
³ 1 1 8 3 0 1
Deactivate LED during the NO READ
Transmission
³ 1 1 9 9 1 7
Enable RTS No Read Pulse A configurable
RTS pulse width transmitted after the NO READ
message has been transmitted.
³ 1 2 0 3 0 3
Disable RTS No Read Pulse