Honeywell MS9520 Scanner User Manual


 
7–3
Same Symbol Time Outs
The length of time before a bar code can be rescanned after it is removed from
the scan field is user-configurable in increments of 50 msecs to 6350 msecs
(6.35 sec).
If using an MS9500 or IS4125, go to page 17–3.
³ 9 1 8 9 0 0
~ Variable Same Symbol Time OutWhile in
configuration mode, scan this bar code followed
by the appropriate code byte sequence (on page
16
1) to set the same symbol time out duration.
This feature is not supported for the MS9500
series or the IS4125, refer to page 17–3
for
additional information.
³ 8 1 8 9 0 0
No Same Symbol Time Out
³ 1 1 8 9 1 7
Infinite Same Symbol Time OutThe scanner
will not repetitively scan the same bar code.
This option overrides the symbol rescan time-outs.
³ 1 1 9 4 1 4
Enable 2 Second Time Out after 2 seconds of
inactivity the laser will turn off and stay off until
the CodeGate button is pressed. This feature is
for the MS5145 only.
³ 1 1 9 4 0 4
Disable 2 Second Time Out
LED Options
³ 1 1 8 3 1 3
Flash Green LED if Rescan AllowedThis
indicates same symbol timeout has elapsed.
³ 1 1 8 3 0 3
Do Not Flash Green LED if Rescan Allowed
³ 1 1 8 3 1 2
Reverse LED FunctionsRed = Laser On
Green = Good Read
³ 1 1 8 3 0 2
* Normal LED FunctionsGreen = Laser On
Red = Good Read