Honeywell MS9520 Scanner User Manual


 
10–3
³ 1 1 5 8 1 5
* Character RTS/CTS Activates/Deactivates
RTS signal for each character.
³ 1 1 5 8 0 5
Message RTS/CTS Activates RTS before
sending the first character and leaves it active
until after the last character has been
transmitted.
³ 1 2 4 5 1 0
Invert RTS Polarity (RSV1)
-12V = Active +12V = Inactive
³ 1 2 4 5 0 0
* Standard RTS PolarityUse standard RTS
polarity
-12V = Inactive +12V = Active
³ 1 2 4 5 1 1
Invert CTS Polarity (RSV2)
-12V = Active, +12V = Inactive,
OK to send Do not send
³ 1 2 4 5 0 1
* Standard CTS Polarity
-12V = Inactive, +12V = Active,
Do not send OK to send
³ 1 2 4 5 1 2
Activate RTS, Do Not Wait for CTS (RSV3)
Activate RTS for transmission but do not wait for
CTS to send.
³ 1 2 4 5 0 2
* Activate RTS, Wait for CTSWait for CTS after
activating RTS.
³ 1 2 4 5 1 3
Test CTS Not Present Before RTS (RSV4)Do
not activate RTS if CTS is already present.
³ 1 2 4 5 0 3
* Do Not Test for CTS Present Before RTS
³ 1 1 5 8 1 7
Enable DTR SupportThe scanner will stop
scanning when the Data Terminal Ready (DTR)
signal goes inactive.
³ 1 1 5 8 0 7
* Disable DTR Support