3. Controller Parameter Setup HRView Function Manual
3-4
3.2. Hi3TB Controller
(1) For Ethernet use:
Condition setup and controller parameter should be the same as follows. The
Baudrate of the Serial Port 2 should have the same setup as BD473 setup. However,
the rest of the communication options should be the same as follows.
Constant Setup Group (1) → 『13: Serial Port』 → 『4: Serial Port 2』
Condition Set → 『27: Serial Port #1』: Set as Sens
Condition Set → 『33: Serial Port #2』: Set as FileMng
08:09:05 *** Serial Port #2 *** A:0 S:4
Press [Enable]+[Arrow].
>_
Save
Baudrate = <38400,19200,9600,4800,2400>
Character length = <7,8> bit
Stop bit = <1,2> bit
Parity bit = <Disable,Odd,Even>
Echo = <Disable,Enable>
08:09:05 *** Condition Set *** A:0 S:4
Press [Enable]+[Arrow].
>_
Service
Previous
Next
Done
29: User coordinate = [ 0]
30: Gun search Ref.point record=<Off,On>
31: Spot welding =<Wd-On,Sq-On,SqOff>
33: Serial port#2 =<FileMng,Sens,BD480>
34: Base of interpolation=<R-tool,S-tool>
08:09:05 *** Condition Set *** A:0 S:4
Press [Enable]+[Arrow].
>_
Service
Previous
Next
Done
1: Mode =<1Step,1Cycle,Continuous>
2: Start=<Internal,External,Remote>
3: External program =<Disable,Enable>
4: Robot lock =<Disable,Enable>
5: Conveyor Oper=<Normal,Simulat.,Test>
7: Search range =[0.0]
8: Search reference Pt. record=<Off,On>
9: Speed rate=[100] Gun =<DSBL,ENBL>
13: Rec speed type=<Standard,[%],[mm/s]>
23: Step go/back max.speed = [250]mm/s
27: Serial port #1 =<FileMng,Sens>