IBM P5 570 Server User Manual


 
Chapter 1. General description 3
1.1 System specifications
Table 1-1 lists the general system specifications of a single p5-570 drawer.
Table 1-1 p5-570 specifications
1.2 Physical package
One p5-570 drawer is packaged in a 4U
2
rack-mounted enclosure, and it is available only in
the rack-mounted form factor. The following sections discuss the major physical attributes
that are found on the p5-570 building block, as shown in Table 1-2 on page 3.
Table 1-2 Physical packaging of the p5-570
Using the p5-570 building block, an installed system can be made of one to four building
blocks. To help ensure the installation and serviceability in non-IBM, industry-standard racks,
review the vendor’s installation planning information for any product-specific installation
requirements. The processor and SP Flex cables present an additional planning requirement.
Description Range
Operating temperature 5 to 35 degrees C (41 to 95 F)
Relative humidity 8% to 80%
Maximum wet bulb 23 degrees C (73 F) (operating)
Noise level 6.5 bels (operating)
Operating voltage 200 to 240 V AC 50/60 Hz
Maximum power consumption 1,300 watts (maximum)
Maximum power source loading 1.37 kVA (maximum configuration)
Maximum thermal output 4,437 Btu
a
/hr (maximum configuration)
a. British Termal Unit (BTU)
2
One Electronic Industries Association Unit (1U) is 44.45 mm (1.75 in).
Dimension One p5-570 building block
Height 174.1 mm (6.85 in)
Width 483 mm (19.0 in)
Depth 790 mm (31.1 in)
Weight 63.6 kg (140 lb)