Symptom / Error FRU / Action in Sequence
173
(Configuration data was
lost.)
1. Select OK in the error
screen; then set the
time and date.
2. Backup battery
3. System board
174
(Configuration error:
Perform“Checking the
Installed Devices List” on
page 55 before changing
any FRUs.)
1. Check Device
Configuration.
2. Hard disk drive
3. System board
184
(POP check sum error.)
Reset the POP (power-on
password) in Easy-Setup.
190
(Depleted battery pack was
installed when the power
was on.)
Go to “Checking the
Battery Pack” on page 35.
191XX
(PM initialization error.)
System board
195
(The configuration read from
the hibernation area does
not match the actual
configuration.)
Check if the configuration
was changed.
For example, check if the
DIMM is added.
196
(Read error occurred in the
hibernation area of the
HDD.)
1. Run the hard disk
drive test.
2. Hard disk drive
1XX System board
2XX
201: Memory data
error.
202: Memory line error
00–15.
203: Memory line error
16–23.
205: Memory test
failure on on-board
memory.
221: ROM to RAM
remap error.
1. Go to “Memory
Checkout” on
page 30.
2. DIMM
3. System board
301, 303, 304, 305, 3XX
(301: Keyboard error.)
1. Go to
“Keyboard/Auxiliary
Input Device
Checkout” on
page 31.
2. Keyboard
3. External numeric
keypad
4. External keyboard
5. Keyboard/mouse cable
6. Subcard
7. System board
ThinkPad 380, 385 (2635) 41