IBM SY27-0345-06 Network Router User Manual


 
MAP 0150: Intermittent Problem Isolation
001
Make sure that:
All cables are attached correctly.
The room temperature is not outside the limits [5° to 41°C (50° to 104°F)].
Did you find a problem?
Yes No
002
Continue with Step 004.
003
Resolve the problem. Then, go to “MAP 0210: Verify Operation” on page 2-23.
004
Is the fan running?
Yes No
005
Are any of the LEDs on? Check the LEDs on both sides of the IBM
2210.
Yes No
006
Make sure that:
The IBM 2210 is plugged into the wall outlet.
The wall outlet has the correct voltage.
The line voltage at the end of the power cord is correct.
Did you find a problem?
Yes No
007
Replace the power supply. Then, go to “MAP 0210: Verify
Operation” on page 2-23.
008
Correct the problem. Then, go to “MAP 0210: Verify Operation” on
page 2-23.
009
(Step 009 continues)
Chapter 2. Problem Determination 2-11