ICP DAS USA 100-700 PLCS Switch User Manual


 
DeviceNet to PLCs or Devices
20
INPUT DATA TABLE
Within the “I/O Data Configuration” screen, use the DOWN arrow key to move the focus to the Input
Data button and press the ENTER key. This action opens the Input Data Table setup screen to allow you
to set up the PLC/Device registers to be mapped to each word of Input data.
Input data is data read from PLC/Device registers and sent from the DN-3000 to the DeviceNet Host.
Each word of Input data (except those reserved for the Command Block and Diagnostics) can be mapped
to specific PLC/Device registers. Mapped registers in the Input Data Table are read from the
PLCs/Devices and placed in the Input data in a round-robin fashion as quickly as the serial
communications link allows.
Use the UP/DOWN arrow keys to scroll through the list of Input data words until the highlight bar is over
the Input word you wish to edit, and press ENTER. A window will open allowing you to edit the
PLC/Device Address, File Number (Allen-Bradley PLCs only) and Register Number mapped to that Input
word.