Intel 1000SX Switch User Manual


 
17
C H A P T E R 3Cable the module
Cabling to a Matrix Module
To accomplish successful link aggregation, the modules must be in-
stalled on the same side of separate switches (for example, both modules
in Slot A).
Note The 1000Base-SX SIM connectors on the 1000SX Advanced
Modules must be connected to ports 2 and 3 on the Matrix
Module for link aggregation to work.
1 Connect the Stack Interface Module port on the 1000SX
Advanced Module to ports 1, 4, 5, or 6. This connects the switch
to the stack.
2 Plug a Stacking Cable into the 1000Base-SX SIM connector on
the 1000SX Advanced Module, and secure it using the latches on
the connector.
3 Plug the other end of the Stacking Cable into port 3 on the Matrix
Module.
1000Base-SX
Stack Interface Module
CLASS 1 LASER PRODUCT
1000SX Advanced Module for 500 Series Switches
5008
A23295.book Page 17 Wednesday, August 30, 2000 1:16 PM