Intermec PD41 Label Maker User Manual


 
Chapter 5 — Setting up the Printer
44 EasyCoder PD41 Printer User’s Guide
The functions 7a-7e are described on the next page.
Extended Testmode: Activating
Step
Data/
Ready Error RtW Button Comment
1 1 Make sure the printhead is
lifted. Press and hold the
Print button and switch the
printer On. Extended
Testmode is activated after
10 seconds.
2 flash flash flash All 3 LEDs flash rapidly four
times. Extended Testmode is
activated. Release button to
continue.
Extended Testmode: Selecting Function
Step
Data/
Ready
Error RtW Button Comment
3 flash flash flash 0 LEDs flash fast four times,
in four-second intervals.
4 flash Lower the printhead.
5 1 Press the Print button and
hold.
6 Release the button when LED combination corresponding to
your choice of function flashes. Then see corresponding
function table below.
7a 0 0 1 Test Label function.
7b 0 1 0 Testfeed Mode Slow
function.
7c 0 1 1 Dump mode function.
7d 1 0 0 Factory default function.
7e111 Exit Extended Testmode.