ioSafe R4 Computer Hardware User Manual


 
P/N: 900-10004-00 REV 02 USER GUIDE, IOSAFE R4
102
On the ioSafe R4 system open up the front vent door using the four thumbscrews on the front of
the unit. All the disk positions are labeled accordingly, identify which disk needs to be replaced.
Remove the failed disk, wait approximately 30 seconds, then install the replacement disk and replace
the front vent door. The front vent door can only be attached in one orientation. If the door doesn’t
seem to fit, try rotating the door to a different orientation.
Warning
Proper seating and latching of the drive is essential to proper operation.
Verify the replacement drive is fully seated and properly latched before
reinstalling the front vent door.
The ioSafe R4 system has hot-swap drive bays, you do not need to power off the ioSafe R4 to
replace a failed disk. You can replace the disk while the system is on. After removing the failed disk,
wait at least 30 seconds until the disk LED blinks, and then insert the new disk.
Re-synchronize the Volume
If you powered off the R4 system to replace the failed disk, turn the power back on. The RAID
volume will automatically re-synchronize the new disk in the background. The process will take
several hours depending on disk size. During the re-sync process, the ioSafe R4 can be used as
normal, although access will be slower until the volume is done re-synchronizing.
You will be notified by email when the re-sync process is complete.
Disaster Recovery Procedure
This section instructs how to recover data following a natural disaster such as fire, water, and/or
physical damage. The first step in any disaster recovery is to contact your ioSafe disaster recovery
team leader. For the most recent version of this document or to locate a team leader go to:
www.iosafe.com/drsupport or call 888-984-6723 x430
Typical steps to recovering from a disaster:
CAUTION: The presence of fire, heat, smoke, unstable structures, or liquid and electricity can
create significant risk of bodily harm. Take care to ensure that your disaster recovery effort is only
performed in safe working conditions.
1)
The first step in recovering data from your ioSafe product is to contact a ioSafe disaster
response team leader: 888-984-6723 x430
2)
Inspect the R4 for physical damage. Remove all cables and inspect the receptacles. Remove
the front and back doors and inspect the inside of the unit. See below for descriptions of what
indicates damage to the R4. If there is no evidence of damage to the R4, plug the cables back
in, power up the unit, and verify proper boot and the presence of your data. During normal
boot, the blue LED will blink and then show steady on.