ioSafe R4 Computer Hardware User Manual


 
P/N: 900-10004-00 REV 02 USER GUIDE, IOSAFE R4
72
SNMP
If you utilize a SNMP management system such as HP OpenView or CA UniCenter to monitor
devices on your network, you can set up the ioSafe R4 device to work within this infrastructure.
To set up SNMP service, check the
Enable SNMP service
checkbox in the
SNMP
tab. You can
leave the
Community name
as
public
, or specify a private name if you have opted for a more
segregated monitoring scheme.
Next, enter a host name or an IP address for
Trap destination
. This is where all trap messages will
be sent. The following system events will generate a trap:
Abnormal power voltage
Abnormal board enclosure temperature
Fan failure
UPS connected
UPS detected power failure
RAID disk sync started and finished
RAID disk added, removed, and failure
Snapshot invalidated
If you wish to limit SNMP access to only a secure list of hosts, specify the hosts in the
Hosts
allowed access
field.
Click
Apply
to save your settings.
When you have saved the SNMP settings on the ioSafe R4, you can import the ioSafe SNMP MIB
to your SNMP client application. The ioSafe MIB can be from the ioSafe Support site at
http://www.iosafe.com.