Using the MAKE/TRIG. system
The RS-485 IN terminal is configured as follows. You can assign the functions to each pin terminal by setting “REMOTE
SYSTEM” (see “PORT F1 – PORT F5” on page 27).
To assign the functions to the pin terminals
For the operation procedure, see page 19.
1. Select “REMOTE SYSTEM” on the set-up menu.
2. Set “CNT. RJ45 IN” to “SET.”
3. Select a pin name (“PORT F1” – “PORT F5”) which you want to assign a function, and then select the function you
want to assign.
• For functions which can be assigned, see the table below.
Functions controlled by MAKE/TRIG. system
Display Functions to be controlled Opening Short-circuiting
INP. A Changes the input to Input A. Invalid Valid
INP. B Changes the input to Input B. Invalid Valid
INP. C Changes the input to Input C. Invalid Valid
INP. D Changes the input to Input D. Invalid Valid
INP. E Changes the input to Input E. Invalid Valid
INP. F Changes the input to Input F. Invalid Valid
POWER Turns on/off the monitor. Power on Power off
ASPECT Changes the aspect ratio. REGULAR FULL
MUTING Turns off or resumes the volume. Muting off Muting on
PIP Turns on/off the PIP mode (see page 18). Invalid Valid
PBP Turns on/off the PBP mode (see page 18). Invalid Valid
– – – No function
NOTE
You cannot assign the same function to different pin terminals.
The TRIG. (trigger) system switches each function by short-circuiting for approx. 1 second.
How to Use External Control (cont.)
This is a female
terminal.
Pin No. Pin name
1 PORT F1
2 PORT F2
3 PORT F3
4 PORT F4
5 PORT F5
6 ENABLE
7 NC
8 GND