Kodak Series 3 Printer User Manual


 
Troubleshooting
44 www.kodak.com/go/support
Battery charging lights
Light status Cause Action/solution
All lights are off The camera is not properly
seated on connector.
Reseat the camera on the
printer dock (page 9).
An unrecognized battery type
is installed, or no battery is
installed.
Install a Kodak EasyShare
Ni-MH rechargeable battery
pack or Kodak EasyShare
Li-Ion rechargeable battery
(page 7).
One steady green light The camera was just placed
on the dock.
None; the dock is checking
the charge status of the
battery.
Ascending steady green
lights
The battery is charging.
Charging is complete when
all three lights are lit.
Leave the camera on the
dock to continue charging or
maintain the charge.
One blinking red light The battery is not properly
installed.
Re-install the battery in the
camera.
The battery or connector pin
is damaged.
Check for damage.
The camera and battery have
been exposed to extreme
temperatures.
Slowly return the camera and
battery to room temperature.
Descending blinking
green lights
The Ni-MH battery pack
refresh cycle is in progress
(discharging). Lights turn off
as discharging progresses.
Leave the camera on the
dock to continue the refresh
cycle (page 10).