Kramer Electronics VP-725XLA Projector User Manual


 
KRAMER: SIMPLE CREATIVE TECHNOLOGY
Configuring and Controlling the VP-725XLA
40
Table 18: Output Functions
Setting Function Range Default
HT Horizontal total 1344
HW Horizontal sync pulse width
136
HS Horizontal active start point
296
HA Horizontal active region
1024
HP Horizontal polarity
VT Vertical total 806
VW Vertical sync pulse width 6
VS Vertical active start point 35
VA Vertical active region 768
VP Vertical polarity
OCLK Output clock 65
Apply Press to apply the settings
Set
Current
Import the values of the currently selected output resolution into
the User Mode Setting
N/A
8.1.9 Verifying Configuration Details via the Info Screen
From the Information screen (see Figure 25) you can verify the scaler source,
the master audio source, the PIP source, the video group source, the output
resolution, the SYNC mode (Frame lock or Free run), as well as the firmware
version number and the audio board firmware version (for example, 1.2 in
Figure 25):
Figure 25: Information Screen