Configuration Via Serial Mode or Telnet Port
WiPort™ User Guide 5-5
Channel 1 and Channel 2 Configuration
Select option 1 Channel 1 or 2 Channel 2 from the Change Setup menu to define
how the serial port responds to network and serial communications. The following
sections describe the configurable parameters within the Channel configuration
menu.
Figure 5-5. Serial and Telnet Port Parameters
Baudrate
The unit and attached serial device, such as a modem, must agree on a speed or
baud rate to use for the serial connection. Valid baud rates are 300, 600, 1200, 2400,
4800, 9600 (default), 19200, 38400, 57600, 115200, 230400, 460800, or 921600.
The current value is displayed in parentheses.
Baudrate (9600) ? _
I/F (Interface) Mode
The Interface (I/F) Mode is a bit-coded byte entered in hexadecimal notation. The
current value is displayed in parentheses.
I/F Mode (4C) ? _
The following table displays available I/F Mode options:
Table 5-2. Interface Mode Options
I/F Mode Option 7 6 5 4 3 2 1 0
RS-232C
(1)
0 0
7 Bit 1 0
8 Bit 1 1
No Parity 0 0
Even Parity 1 1
Odd Parity 0 1
1 stop bit 0 1
2 stop bits
(1)
1 1
(1) 2 stop bits are implemented by the software. This might influence performance.