Lantronix 900-618 Server User Manual


 
7. Setup Mode: Channel Configuration
This chapter explains how to configure the serial port.
Channel 1 (Option 1) or Channel 2 (Option 2)
Select Channel 1 (option 1) or Channel 2 (option 2) from the Change Setup menu to
define how the serial port responds to network and serial communications. The
following sections describe the configurable parameters within the Channel
configuration menu.
Figure 7-1. Serial Port Parameters
Baudrate (9600) ?
I/F Mode (4C) ?
Flow (00) ?
Port No (10001) ?
ConnectMode (C0) ?
Send '+++' in Modem Mode (Y) ?
Show IP addr after 'RING' (Y) ?
Auto increment source port (N) ?
Remote IP Address : (000) .(000) .(000) .(000)
Remote Port (0) ?
DisConnMode (00) ?
FlushMode (00) ?
DisConnTime (00:00) ?:
SendChar 1 (00) ?
SendChar 2 (00) ?
Baudrate
The unit and attached serial device, such as a modem, must agree on a speed or
baud rate to use for the serial connection. Valid baud rates are 300, 600, 1200, 2400,
4800, 9600 (default), 19200, 38400, 57600, 115200, and 230400 bits per second.
xPico also supports high-performance baud rates of 460800 and 921600 bits per
second. (See CPU Performance on page 55).
Baudrate (9600) ? _
xPico User Guide 40