Lantronix 900-618 Server User Manual


 
7: Setup Mode: Channel Configuration
Message
Meaning
Numeric Response
0
OK
1
Connected
2
Ring
3
No Carrier
4
Error
Received commands must begin with the two-character sequence AT and be
terminated with a carriage return character.
The unit ignores any character sequence received not starting with AT, and only
recognizes and processes single AT-style commands. The unit treats compound AT
commands as unrecognized commands.
If the Full Verbose option is in effect, the unit responds to an unrecognized
command string that is otherwise formatted correctly (begins with AT and ends with
carriage return) with the "OK" message and takes no further action.
If the Numeric Response option is in effect, the unit responds to an unrecognized
command string that is otherwise formatted correctly with the "OK" message and
takes no further action.
When an active connection is in effect, the unit transfers data and does not process
commands received from the serial interface.
When a connection is terminated or lost, the unit reverts to command mode.
When an active connection is in effect, the unit terminates the connection if it
receives the following sequence from the attached serial device:
No serial data is received for one second.
The character sequence +++ is received, with no more than one second between
each two characters.
No serial data is received for one second after the last + character. At this time,
the unit responds affirmatively per the selected echo/response mode.
The character string ATH is received, terminated with a carriage return. The unit
responds affirmatively according to the selected echo/response mode and drops
the network connection. The serial interface reverts to accepting command
strings.
If this sequence is not followed, the unit remains in data transfer mode.
Table 7-8. Modem Mode Commands
Modem Mode
Command
Function
ATDTx.x.x.x,pppp,
ATDTx.x.x.x/pppp,
or
ATDTx.x.x.x:pppp
Makes a connection to an IP address (x.x.x.x) and a remote port
number (pppp).
ATDTx.x.x.x
Makes a connection to an IP address (x.x.x.x) and the remote port
number defined within the unit.
xPico User Guide 48