XPort® Pro Lx6 Embedded Device Server User Guide 27
6: Line and Tunnel Settings
The XPort Pro Lx6 embedded device server contains one line using a standard RS232/RS485
serial port. This line may be configured to operate in the following modes:
RS232
RS485 Full Duplex (also compatible with RS-422)
RS485 Half Duplex, with and without termination impedance
All serial settings such as Baud Rate, Parity, Data Bits, etc, apply to these lines.
Line Settings
The Line Settings allow configuration of the serial lines (ports).
Some settings may be specific to only certain lines. Such settings are noted below.
Table 6-1 Line Configuration Settings
Line Settings Description
Name Enter a name or short description for the line, if desired. By default, there is
no name specified. A name that contains white space must be quoted.
Interface Set the interface type for the Line. The default is RS232 for Line 1.
Choices are:
RS232
RS485 Full-Duplex
RS485 Half-Duplex
Termination Select to Enable or Disable Line Termination. The default is Disable.
Note: This setting is only relevant for Line 1 with Interface type RS485 Half-
Duplex.
State Select to Enable or Disable the operational state of the Line. The default is
Enable.
Protocol Set the operational protocol for the Line. The default is Tunnel. Choices are:
None
Tunnel = Serial-Network tunneling protocol.
Baud Rate Set the Baud Rate (speed) of the Line. The default is 9600.
Any set speed between 300 and 921600 may be selected: 300, 600, 1200,
2400, 4800, 9600, 19200, 38400, 57600, 115200, 230400, 921600. When
selecting a Custom baud rate, you may manually enter any value between
300 and 921600.
Note: Custom baud rates are not supported when a line is configured for
Command Mode.
Parity Set the Parity of the Line. The default is None.
Data Bits Set the number of data bits for the Line. The default is 8.
Stop Bits Set the number of stop bits for the Line. The default is 1.
Flow Control Set the flow control for the Line. The default is None.