10: Maintenance and Diagnostics Settings
XPort® Pro Lx6 Embedded Device Server User Guide 55
Using the CLI
To enter the command level: enable
Using XML
Not applicable.
Log
Table 10-10 Log Settings
To Configure the Diagnostic Log Output
Using Web Manager
To configure the Diagnostic Log output, click Diagnostics in the menu and select Log.
Using the CLI
To enter the command level: enable -> config -> diagnostics -> log
Using XML
Include in your file:
<configgroup name=”diagnostics”>
and
<configitem name=”log”>
Memory
The memory information shows the total, used, and available memory (in bytes).
Note: Used memory size is not shown in Web manager.
To View Memory Usage
Using Web Manager
To view memory information, click Diagnostics in the menu and select Memory.
Diagnostics: Log Description
Output Select a diagnostic log output type:
Disable - Turn off the login feature.
Filesystem - Directs logging to /log.txt.
Line 1- Directs logging to the selected serial line.
Max Length Set the maximum length of the log.txt file. Max length must range from 10 - 128
kbytes.
Note: This setting becomes available when Filesystem is selected.