Device Installer
Table 11 - Manual Connection Address Example
Command String Result if remote IP is 129.1.2.3 and remote port is 1234
C121.2.4.5/1 Complete override; connection is started with host 121.2.4.5, port 1
C5 Connect to 129.1.2.5, port 1234
C28.10/12 Connect to 129.1.28.10, port 12
C0.0.0.0/0 Enter Monitor Mode
Autostart (Automatic Connection):
If Autostart is enabled, the unit automatically connects to the remote IP
address and remote port specified when the firmware starts.
Hostlist: If you enable this option, the unit scrolls through the hostlist until it
connects to a device listed in the hostlist table. Once it connects, the unit
stops trying to connect to any others. If this connection fails, the unit
continues to scroll through the table until it is able to connect to another IP
in the hostlist.
Hostlist supports a minimum of 1 and a maximum of 12 entries. Each entry
contains the IP address and the port number. The host list will be disabled
for Manual Mode and for Modem Mode. The unit will not accept a data
connection from a remote device when the host list option is enabled.
Baudrate (9600)
I/F Mode (4C)
Flow (00)
Port No (10001)
ConnectMode (21)
Send ‘+++’ in Modem Mode (Y) ?
Auto increment source port (N) ?
Hostlist :
01. IP : 010.010.010.001 Port : 00023
02. IP : 010.010.010.002 Port : 00023
03. IP : 010.010.010.003 Port : 00023
Change Hostlist ? (N)
Hostlist Retrycounter (3)
Hostlist Retrytimeout (250)
DisConnMode (00)
FlushMode (00)
DisConnTime (00:00) :
SendChar 1 (00)
SendChar 2 (00)
Figure 11 - Hostlist Option
To use the Hostlist option, follow these steps:
1. Enter a Connect Mode of 0x20 (2X). The menu shows you a list of current entries already defined in
the product.
NET485 User Guide 3-31