Configure
3-10
UDS-10 User Guide
3.4 Configuring via the Setup Mode Window
3.4.1 Using a Telnet Connection
To configure the unit over the network, establish a Telnet connection to port 9999.
Note: If you use the Telnet to Device icon on the Device Installer Device Management
window OR a serial port login to establish the connection, skip steps 1and 2.
1. From the Windows Start menu, click Run and type the following command, where
x.x.x.x is the IP address and 9999 is the unit’s fixed network configuration port number.
telnet x.x.x.x 9999
Note: Be sure to include a space between the IP address and 9999.
2. Click OK.
3. The Lantronix Universal Device Server window displays.
*** Lantronix Universal Device Server ***
Serial Number 7218033 MAC address 00:20:4A:72:46:71
Software version 04.5 (011025)
Press Enter to go into Setup Mode
4. To enter the Setup Mode, you must press Enter within 5 seconds. The configuration
settings will appear. See Figure 13 - Setup Mode Window.
Note: The following line appears only with IAP Standard Tunnel Protocol Firmware.
Model: Device Server Plus+! (Firmware Code: AQ)
5. Select an option on the menu by entering the number of the option in the Your choice ?
field and pressing Enter.
6. To enter a value for a parameter, type the value and press Enter, or to confirm a current
value, just press Enter.
7. When you are finished, save the new configurations (option 9). The unit will reboot.