Lantronix 10 Network Card User Manual


 
Configure
3-24
UDS-10 User Guide
Send Characters: If 2-Byte Send Character Sequence is enabled, the unit interprets the
sendchars as a 2-byte sequence; if not set, they are interpreted independently.
If Send Immediately After Characters is not set, any characters already in the serial buffer
are included in the transmission after a "transmit" condition is found. If set, the unit sends
immediately after recognizing the transmit condition (sendchar or timeout).
Note: A transmission might occur if status information needs to be exchanged or an
acknowledgment needs to be sent.
3.6.11 DisConnTime (Inactivity Timeout)
Use this parameter to set an inactivity timeout. The connection is dropped if there is no
activity on the serial line before the set time expires. Enter time in the following format:
mm:ss, where m is the number of minutes and s is the number of seconds. To disable the
inactivity timeout, enter 00:00.
3.6.12 Send Characters
You can enter up to two characters in hexadecimal representation in the parameters
"sendchar." If a character received on the serial line matches one of these characters, it is sent
immediately, along with any awaiting characters, to the TCP connection. This minimizes the
response time for specific protocol characters on the serial line (for example, ETX, EOT,
etc.). Setting the first sendchar to 00 disables the recognition of the characters. Alternatively,
the two characters can be interpreted as a sequence (see Pack Control on page 3-23).
3.6.13 Telnet Terminal Type
This parameter appears only if the terminal type option is enabled in Disconnect Mode (see
DisConnMode on page 3-21 above). If this option is enabled, you can use the terminal name
for the Telnet terminal type. Enter only one name.
If the terminal type option is enabled, the unit also reacts to the EOR (end of record) and
binary options, which can be used for applications like terminal emulation to IBM hosts.
3.6.14 Channel (Port) Password
This parameter appears only if the channel (port) password option is enabled in Disconnect
Mode (see DisConnMode on page 3-21). If set, you can set a password on the serial port.