Lantronix 10 Network Card User Manual


 
UDP
8-8
UDS-10 User Guide
8.3.1 Channel Parameters
Use the following table to select setup record parameters for Channels 1:
Table 22 - Channel Parameters
Byte(s)
(Channel 1)
Function
16
Interface Mode (see
Table 23 - Interface Mode Options)
17 Line Speed
Bits 7-5: Reserved
Bits 4-0: Baud Rate (see
Table 25 - Baud Rate Settings)
18
Flow Control (see
Table 26 - Flow Control Options)
19 Reserved
20-21 Own TCP port low-byte, high-byte (Intel)
22-23 Remote TCP port low byte, high-byte (Intel)
24-27 Remote IP address (low/high low/high)
28
Connect Mode (see
Table 27 - Connect Mode Options)
29
Disconnect Mode (see
Table 28 - Disconnect Mode Options)
30 Disconnect w/ inactivity time-out, minutes (00 if unused)
31 Disconnect w/ inactivity time-out, seconds (00 if unused)
32-33 Characters to trigger send immediately (sendchar)
34
Flush mode (see
Table 29 - Flush Mode Options)
35
Pack Control (see
Table 30 - Pack Control Options)
36-47 Reserved (0)
48-63 a) Terminal name for Telnet terminal type option (15 characters max),
0-terminated. If set and Bit 6 in Disconnect Mode is set, Telnet
connection will be assumed.
b) Password for Passworded Socket Connection (Bit 4 in Disconnect
Mode Set).