Lantronix 10 Network Card User Manual


 
UDP
8-10
UDS-10 User Guide
8.3.3 Baud Rate
The Device Server and attached serial device must agree on a speed or baud rate to use for
the serial connection. Use the following table to select Baud Rate settings:
Table 25 - Baud Rate Settings
Speed
(bps)
Hex
38400 00
19200 01
9600 02
4800 03
2400 04
1200 05
600 06
300 07
115200 08
57600 09
8.3.4 Flow Control
Flow control sets the local handshaking method for stopping serial input/output. Generally,
flow control is not required if the connection is used to pass a blocked protocol with block
sizes less than 1k (ACK/NAK) and/or speeds of 19200 or less. Use the following table to
select Flow Control options:
Table 26 - Flow Control Options
Option Hex
No flow control 00
XON/XOFF flow control 01
Hardware handshake with RTS/CTS lines 02
XON/XOFF pass characters to host 05