Lantronix UDS1100 Network Card User Manual


 
5: Configuration via Telnet or Serial Port (Setup Mode)
UDS1100 User Guide 36
Figure 5-1. MAC Address
3. To enter Setup Mode, press Enter within 5 seconds. The configuration settings
display, followed by the Change Setup menu.
Figure 5-2. Setup Menu Options
4. Select an option on the menu by entering the number of the option in the Your
choice ? field and pressing Enter.
5. To enter a value for a parameter, type the value and press Enter, or to confirm a
current value, just press Enter.
6. When you are finished, save the new configuration (option 9). The unit reboots.
Serial Port Connection
To configure the unit through a serial connection:
1. Connect a console terminal or PC running a terminal emulation program to your
unit's serial port. The default serial port settings are 9600 baud, 8 bits, no
parity, 1-stop bit, no-flow control.
2. Reset the UDS1100 unit by cycling the unit's power (turning the power off and
back on). Immediately upon resetting the device, enter three lowercase x
characters (xxx).
Note: The easiest way to enter Setup Mode is to hold down the x key at
the terminal (or emulation) while resetting the unit. You must do this
within three seconds of resetting the UDS1100.
At this point, the screen display is the same as when you use a Telnet connection. To
continue, go to step 3 in Telnet Connection, above.
Exiting Setup Mode
To exit setup mode:
You have two options:
To save all changes and reboot the device, select option 9 Save and exit from
the Change Setup menu. All values are stored in nonvolatile memory.
To exit the configuration mode without saving any changes or rebooting. select
option 8 Exit without save from the Change Setup menu.