8: Setup Mode: Advanced Settings
UDS1100 User Guide 58
Default Settings (Option 7)
Select 7 to reset the unit’s Channel 1 configuration and expert settings to the default
settings. The server configuration settings for IP address, gateway IP address, and
netmask remain unchanged. The configurable pins’ settings also remain unchanged.
The specific settings that this option changes are listed below:
Channel 1 Configuration Defaults
Baudrate 9600
I/F Mode 4C (1 stop bit, no parity, 8 bit, RS-232C)
Own TCP port number 10001
Connect Mode C0 (always accept incoming connection; no active
connection startup)
Hostlist retry counter 3
Hostlist retry timeout 250 (msec)
Start character for serial channel 1 0x0D (CR)
All other parameters 0
Expert Settings Defaults
TCP Keepalive time in s 45
ARP Cache timeout in s 600
Disable Monitor Mode @ bootup No
HTTP Port Number
(1-65535)
80
MTU Size (512 – 1400) 1400
Enable alternate MAC No ( for OEM use only)
Ethernet Connection Type 0 (auto-negotiate)
Security Settings Defaults
Disable SNMP No
SNMP community name public
Disable Telnet setup No
Disable TFTP Firmware Update No
Disable Port 77FEh No
Disable Web Server No