Minicom Advanced Systems 5UM7017 Network Hardware User Manual


 
AccessIT
40
Warning – Problem with the device. See the Devices page on page 40 for
more information.
Uploading – Device is receiving new firmware from AccessIT Manager.
Updating device Device is receiving an updated configuration from
AccessIT Manager.
Rebooting - Device reboots upon any Network parameter change, or firmware
upgrade.
Connecting – AccessIT send or receives the Device Discovery message.
Version – Displays the device firmware version number.
Description – Identifying description of the device as input by the administrator
when configuring the device.
8.1 Setting each IP device to be AccessIT enabled
In order to be managed by AccessIT, all Minicom IP devices must be configured to
be Centralized Management enabled. See section 4 on page 17.
Tip! Since IP devices only appear in the New Devices list once they are
Centralized Management enabled, make each IP device Centralized Management
enabled in a certain order with a suitable time gap, so that you can identify the
unit’s location.
8.2 Configuring the IP devices
Configure a new IP device as follows:
1. In the New Devices section click the MAC address of an IP device. The
General tab of the Devices page appears, see Figure 36.
Figure 36 Devices page - General tab
Type – IP device type, PX, IP Control etc. (Read-only field).