Problem Solving 5-33
Table 5-3. POST Error Codes and Messages (continued)
Error Code and Message Description Action
0B6F DIMM group with
error is enabled
Memory error was detected. The system is forcibly started because
errors are detected in all memory
devices. Contact your service
representative to replace the DIMM
boards.
0B70 The error occurred
during temperature
sensor reading
An error was detected in the
middle of detection of abnormal
temperature.
0B71 System Temperature
out of the range
Abnormal temperature was
detected.
0B74 The error occurred
during voltage
sensor reading
An error occurred during detection
of voltage.
0B75 System Voltage out
of the range
Abnormal system voltage was
detected.
0B78 The error occurred
during fan sensor
reading
An error was detected during read
of FAN sensor.
Contact your service representative to
replace the I/O riser board, or system
I/O board or baseboard.
0B7C The error occurred
during the redundant
power module
confirmation
An error occurred while redundant
power supply was configured.
Contact your service representative to
replace the power unit.
0B80 BMC Memory Test
Failed.
BMC SRAM test error
0B81 BMC Firmware Code
Area CRC check
failed.
CRC error occurred in BMC code
area.
0B82 BMC core hardware
failure.
A firmware task cannot be ready
due to BMC hardware error.
0B90 BMC Platform
Information Area
Corrupted.
The platform information area of
BMC is damaged.
0B93 BMC SDR
Repository empty.
No BMC SDR data exists.
Contact your service representative to
replace the I/O riser board.
0B95 BMC FRU device
failure.
Access to SROM that contains the
chassis information failed.
Contact your service representative to
replace the baseboard.
0B96 BMC SDR
Repository failure.
Access to FMEM sector that
contains SDR information failed.
Contact your service representative to
replace the riser card.
0BA0 Address Array on
CPU Box #1 error
An error was detected in the
address area of the third cache for
the CPU backboard #1.
0BA1 Address Array on
CPU Box #2 error
An error was detected in the
address area of the third cache for
the CPU backboard #2.
0BA2 Data Array on CPU
Box #1 error
An error was detected in the data
area of the third cache for the
CPU backboard #1.
0BA3 Data Array on CPU
Box #2 error
An error was detected in the data
area of the third cache for the
CPU backboard #2.
Contact your service representative to