– Emergency – The highest warning level. If the device is down or not functioning
properly, an emergency log message is saved to the specified logging location.
– Alert – The second highest warning level. An alert log is saved, if there is a serious
device malfunction; for example, all device features are down.
– Critical – The third highest warning level. A critical log is saved if a critical device
malfunction occurs; for example, two device ports are not functioning, while the rest
of the device ports remain functional.
– Error – A device error has occurred; for example, if a single port is offline.
– Warning – The lowest level of a device warning. The device is functioning, but an
operational problem has occurred.
– Notice – Provides device information.
– Informational – Provides device information.
– Debug – Provides debugging messages.
– RAM Logs – Defines the minimum severity level from which logs are sent to the RAM
Log kept in RAM (Cache).
– Log File – Defines the minimum severity level from which logs are sent to the log file
kept in FLASH memory.
2. Define the Enable Logging and Severity fields.
3. Click . The log parameters are set and the device is updated.