FS728TP Smart Switch Software User Manual
Configuring the Device Using Your Browser 5-50
v2.0, November 2006
– Checked – Enables PoE traps on the device.
– Unchecked – Disables PoE traps on the device. This is the default value.
– Interface – Indicates the specific interface for which PoE parameters are defined. PoE
parameters are assigned to the powered device that is connected to the selected interface.
– Admin Mode – Indicates the device PoE mode. The possible field values are:
– Enable – Enables the Device Discovery protocol and provides power to the device
using the PoE module. The Device Discovery Protocol enables the device to discover
Powered Devices attached to the device interfaces and to learn their classification.
This is the default setting.
– Disable – Disables the Device Discovery protocol and stops the power supply to the
device using the PoE module.
– Priority Level – Determines the port priority if the power supply is low. The field default
is low. For example, if the power supply is running at 99% usage, and port 1 is prioritized
as high, but port 3 is prioritized as low, port 1 is prioritized to receive power and port 3
may be denied power. The possible field values are:
– Low – Defines the PoE priority level as low. This is the default level.
– Medium – Defines the PoE priority level as Medium.
– High – Defines the PoE priority level as high. This is the highest PoE priority level.
– Class – Indicates the amount of power assigned to the powered device connected to the
selected interface. The powered device classifies devices, and the devices use the
classification information. The field values are:
– Class 0 – Indicates that the maximum power level at the input of the Powered Device
is 15.4 watts.
– Class 1 – Indicates that the maximum power level at the input of the Powered Device
is 4.0 watts.
– Class 2 – Indicates that the maximum power level at the input of the Powered Device
is 7.0 watts.
– Class 3 – Indicates that the maximum power level at the input of the Powered Device
is 15.4 watts.
– Class 4 – Treated as Class 0.
– Output Voltage – Displays the Output Voltage in watts.
– Output Current (ma) – Displays the Output current in milliamps.