TROUBLESHOOTING
PROBLEM:
SOLUTION:
Keyboard Errors
Check cable connections on each CPU and the switch.
NOTE: If the cable from a CPU’s keyboard port is disconnected from the NTI Universal KVM switch while
power is ON, turn the power OFF to the CPU before plugging the cable back in.
PROBLEM:
SOLUTION:
No Video
Check cable connections on each CPU and the switch.
Verify that the keyboard and video cables are connected from each CPU to matching ports. After
reconnecting, the CPU may need to be re-booted in order to sense that the monitor is connected.
PROBLEM:
SOLUTION:
No Mouse Movement
Check cable connections of mouse to keyboard
Verify that mouse driver was loaded. (If you are unsure how to do this, contact your system
administrator.)
PROBLEM:
Monitor shuts down while working with OSD menu
Disengage or increase time setting of CPU monitor’s “sleep” mode from the BIOS and/or control panel
display settings. The CPU does not sense activity while in the OSD menu.
GENERAL NOTE: Verify that the port 1 LED (on the front panel of the KVM switch) illuminates when the power switch is
turned ON. If it doesn’t, call NTI for assistance.
Turn ON power to the NODEMUX first, then to the CPUs.
Always turn power ON in this sequence.